EZC

CEZC series of MCCB perfect function,ensure 100% reliability and continuity of power supply.

Usage
CEZC series of MCCB are used in distribution network of AC 50/60Hz,rated operationsal voltage 440V and rated current from 15A to 63A,It is used for
distributing power and protecting circuit,power and electrical equipment from
overload and short circuit damage,which improve the reliability and continuity
of power supply.

Perfect function
The breaking capacity covers the common breaking in Level Ⅱpower distribution
   areas and electromechanical market:25KV,36KV and 50KV.Including 1P,2P,3P and 4P products.
Comprehensive range of profection,including low-voltage distribution systems
   protection,motor protection and earth leakage protection.

TypeEZC100  
CommectionsFixed  
Pole1,2,3,4  
Product appearance
Electrical characteristics as per IEC60947 and EN60947-2
Rated current (A) ln (A)15,20,30,40,50,60,75,80,100  
Rated voltageUe(V)AC 50/60Hz440  
Rated insulation voltageUi(V)AC690  
Rated impulse voltageUimp (kV)AC6  
Breaking capacity levels F H  
lsolation Function N  
  
Utilization categoryA  
Eudurance(C-O cycles)Mechanical10000  
Electrical 440V2000  
Protection  
ReleaseThermal mangnetic  
Overload protectionY  
Short-circuit protectionY  
Earth-leakage protectionN  
Indication and control auxiliaries  
Auxiliary control AX and Alarm contact ALY  
Combinded AX + ALY  
SHT shunt release 24V,220V,380V
UVR under-voltage releaseY
Installation/connection
AccessoriesTherminal extensionsY
 Therminal shieldsN
 Phase barriersY
Dimensions(mm) 1P130X25X81
  2P130X50X81
  3P130X75X81
  4P130X100X81
TypeEZC250  
CommectionsFixed  
Pole3,4  
Product appearance  
Electrical characteristics as per IEC60947 and EN60947-2
Rated current (A) ln 40℃100,125,160,200,250  
Rated voltageUe(V)AC 50/60Hz440  
Rated insulation voltageUi(V)AC690  
Rated impulse voltageUimp (kV)AC6  
Breaking capacity levels E M  
lsolation Function N  
  
Utilization categoryA  
Eudurance(C-O cycles)Mechanical8500  
Electrical 440V1500  
Protection  
ReleaseThermal mangnetic  
Overload protectionY  
Short-circuit protectionY  
Earth-leakage protectionN  
Indication and control auxiliariesN  
Auxiliary control AX and Alarm contact ALY  
Combinded AX + ALY  
SHT shunt release 24V,220V,380V  
UVR under-voltage releaseY  
Installation/connection  
AccessoriesTherminal extensionsY  
 Therminal shieldsN  
 Phase barriersY  
Dimensions(mm) 3P165X105X85.5  
  4P165X140X85.5  
 Auxiliary seitch can indicate the state of breaker remotely.Therefore,it can be used for indication,electrical chain,relay control and so an.
 
Electrical characteristics 
  ln:630
Rated thermal current(A) 5
Working current(A)220-240V5
 380/440V5
24/48V5
   
  Voltage release coil  
  Voltage release coil can trip the circuit breaker by contronlling the signal.
  Unde Voltage Release(UVR/UVRN)
This release trips the circuit breaker when the control voltage drops be low a triping
threshold.
Tripping threshold between 0.35 and 0.7 times the rated voltage.
Circuit breaker closing is possible only if the voltage exceeds 0.85 times the rated
voltage,compliance with IEC60947-2. 
   
Shunt Trip(SHT)  
  This release trip the circuit breaker when the control voltage rises above 0.7 x Un.
  Control signals can be of the impulse type(≧20ms)or maintained.
     
Function  
AX(ON/OF):Indicates the position of the circuit breaker contacts
AL(trip indication):Indicates that the circuit breakers has tripped due to an 
overload,a short-circuit,or operation of a voltage release. 
   

                                          CEZC-100/CEZD-100/CESV-100E

                                                CEZC/CEZD-160-250